Chapter 9 Annex
2104.6536.72 - 9.3 - E-1
1.2 External Interfaces
1.2.1 R&S SX801 Exciter – Front Panel
1.2.1.1 X61 (RF) – RF MONITOR: RF Test Output
SMA female
Note This interface is present only if an internal 10 dB amplifier is installed (option SX801B41).
1.2.2 R&S SX801 Exciter – Rear Panel
1.2.2.1 X1: Power Feed
AC option
Low-temperature connector
W6010 470 MHz to 862 MHz
P
rms,nom
= 2to5dBm
X60/X10 RF signal from exciter to
input of base amplifier
Signal name Direction Range of values Contact Comment
RF MONITOR Output Monitoring signal
downstream of
amplifier:
-7 dBm RMS /
0 dBm peak ± 2 dB
X61.1 R
i
= 50 ,
for monitoring only
GND Bidirect. X61.2
Signal name Direction Value range Contact Comment
1)
L1 Bidirect. 90 VAC to 265 VAC,
I 1.5 A,
50 Hz to 60 Hz,
± 10%
X1.L AC power supply
N Bidirect. X1.N AC power supply
PE Bidirect. X1.PE AC power supply
Signal name Direction Range of values Contact Comment