Chapter 5 Operating
2104.6536.72 - 5.51 - E-1
Transmitter: Used to select the TV standard, to activate message suppression for the
parallel remote interface, to determine the behavior of the parallel remote interface when
switching between analog TV and digital TV, to activate the time scheduler for multistan-
dard operation and to enter the transmitter name
Configuration: Used to select and configure the TV standards for time-controlled
switchover
Time Scheduler: Used to define switching times for time-controlled switchover of the
standards
Compared to the standalone exciter, the menu window System > Tx Type > Transmitter
has been extended to include two transmitter-specific parameters.
The other menu windows in the submenu are the same as those in the standalone exciter
(see the manual for the R&S SX801, "Operating" chapter).
3.3.1 System > Tx Type > Transmitter
The menu window System > Tx Type > Transmitter is used, for example, to set the input
interfaces and the signal processing to the relevant TV standard. You can also activate a
time scheduler for multi-standard operating mode and enter special settings for the parallel
remote control interface.
Setting item Explanation
Tx Type Select the TV standard: ATV, DVB or ATSC
The instrument reboots automatically when the TV standard is switched
over. Signal processing is also switched over.
Reset On Program
Off
In the ON switch position, a Reset Fault is automatically triggered when
the RF output is locked.
Time Scheduler Enable or disable time-controlled tasks with the aid of the time scheduler
Par I/O DTV setting It is possible to switch over from ATV to DTV via the parallel remote con-
trol interface. The switch defines which DTV standard will be used.
Par I/O Inhibit Status Switches to message suppression for the parallel remote control inter-
face
OFF: Message suppression is not activated; messages via the paral-
lel remote interface are also output during local operation
ON: Message suppression is activated; during local operation, no
messages are output via the parallel remote interface