Chapter 9 Annex
2104.6536.72 - 9.2 - E-1
1.1.2 RF Signals
1.1.2.1 Single Transmitter with Base Amplifier (R&S SCV8x01E)
1.1.2.2 Single Transmitter with Base and Extended Amplifier (R&S SCV8x02E)
/AC_OK Internal pull up,
Ri = 1000
X5.15/X11.15 AC voltage phase
monitor
– 0 V: AC ok
– Open: No AC, phase
failure, overvoltage
and undervoltage
SHUT_DOWN Internal pull up,
Ri = 1000
X5.8/X11.8 – Closed with respect
to GND: Absorber ok
– Open: Absorber fail
Signal name Direction Range of values Contact Comment
W6010 470 MHz to 862 MHz
P
rms,nom
=2 to 5dBm
X60/X10 RF signal from exciter to
input of base amplifier
W400 470 MHz to 862 MHz
Set transmitter out-
put power: max.
55 dBm
X2 RF signal from output of
base amplifier to antenna
(optional to bandpass filter)
Signal name Direction Range of values Contact Comment
W234 470 MHz to 862 MHz
Half transmitter out-
put power: max.
55 dBm
X2/X34 RF signal from output of
base amplifier to combiner
input of extended amplifier
W236 470 MHz to 862 MHz
Half transmitter out-
put power: max.
55 dBm
X2/X36 RF signal from output of
extended amplifier to com-
biner input of extended
amplifier
W400 470 MHz to 862 MHz
Set transmitter out-
put power: max.
57.8 dBm
X35 RF signal from combiner
output of extended ampli-
fier to antenna (optional to
bandpass filter)
W1015 470 MHz to 862 MHz
P
rms,nom
= -2to1dBm
X15/X10 RF signal from splitter of
base amplifier to input of
extended amplifier