EasyManua.ls Logo

Rohde & Schwarz SCV8000E/R - Page 130

Rohde & Schwarz SCV8000E/R
214 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5 Operating
2104.6536.72 - 5.48 - E-1
Input Ok Valid transport stream present at active input
In the case of hierarchical coding, the input is OK if valid trans-
port streams are present at both inputs (for HP stream and LP
stream).
W Invalid transport stream at active input (combined with the setting
Type of Loss of Input = Warning, see section "Exciter > Input >
Input Automatic")
F Invalid transport stream at active input (combined with the setting
Type of Loss of Input = Fault, see section "Exciter > Input >
Input Automatic")
Input [1/2] Con-
nect
Ok Input signal is present at the input TS 1/TS 2
W Input signal has not been detected
- OFF - Input is not present at the input TS 1/TS 2
Reference Ok External reference frequency is present and OK
W External reference frequency is not OK
F External reference frequency is not OK and the Fail Delay Time
set in the Exciter > Reference > Common menu has expired
- OFF - External reference frequency is not present but it is also not
needed
Option Key Ok All necessary software options are enabled
W A temporary license code for a software option will expire shortly
F One or more necessary software options are not enabled
Sum Warning W One or more warnings are active
Output Termi-
nated
Ok Exciter output terminated
F Exciter output open
Self Test F A hardware fault has occurred in one or more modules; for fur-
ther information on errors see logbook
Ok Self test passed
Temperature Ok Temperature of the modules is OK
F At least one module is overheating
Fan Ok Fan is OK
W A fan has failed; there is a possibility of overheating
Display LED Explanation

Table of Contents