Chapter 5 Operating
2104.6536.72 - 5.44 - E-1
HP1 Connect Ok Input signal is present at TS 1
- OFF - No input signal present at TS 1
HP1 Seamless Indicates the status of seamless input switchover for TS 1
(seamless switching)
Seamless switching is activated and deactivated in the menu
window Exciter > Input > Input Automatic using the Seamless
Switching switch.
On Operating input and standby input are synchronized
- OFF - Inputs cannot be synchronized
HP1 Preselect Ok TS 1 is the preselected operating input
- OFF - TS 1 is the standby input
HP1 Active Ok TS 1 is currently the active input
- OFF - TS 1 is currently the inactive input
HP1 MIP fail W No MIP at input TS 1. Possible reasons:
in the SFN: no MIP in input data stream
in MFN: No MIP in input data stream and in the menu window
Exciter > DVB > TPS the setting TPS Source > MIP is
selected
- OFF - MIP is present
LP1 Connect Ok Input signal is present at TS 2
- OFF - No input signal present at TS 2
LP1 Seamless Indicates the status of seamless input switchover for TS 2
(seamless switching)
Seamless switching is activated and deactivated in the menu
window Exciter > Input > Input Automatic using the Seamless
Switching switch.
On Operating input and standby input are synchronized
- OFF - Inputs cannot be synchronized
LP1 Preselect Ok TS 2 is the preselected operating input
- OFF - TS 2 is the standby input
LP1 Active Ok TS 2 is currently the active input
- OFF - TS 2 is currently the inactive input