Chapter 5 Operating
2104.6536.72 - 5.31 - E-1
Once again, unavailable parameters receive the reply NoSuchName, e.g. parameters from
the transmitter A8 if only a 4+1 system is available (see module compliances under
.1.3.6.1.4.1.2566.127.1.2.167.5.5.2).
Setting alarms
The transmitter-specific alarms offer an extensive range of configuration possibilities.
Depending on the available system, it is possible to set detailed alarms: for example, for
every item of status information in every amplifier in every rack of every transmitter in a me-
dium-power n+1 system. In addition, it is also possible to assign a freely selectable priority
and to check the current status.
In the illustration above, the following information is contained in the highlighted row (de-
pending on the used MIB; here: DVB n+1 medium-power system):
Tab. 1 "Instance" column (1.1.1.4.84) in numeric order
Tab. 2 Meaning of other columns
The columns containing the value Not accessible are "index" columns (identified by IDX).
OIDs of these columns cannot be queried; they are used for internal purposes only.
Position of code
number
Meaning of position Value Meaning of value
1 Transmitter 1 Transmitter TxB
2 Output stage 1 Output stage A
3 Transmitter rack 1 Transmitter rack No. 1
4 Amplifier 4 Amplifier No. 4
5 Event 84 Amplifier ON/OFF
Column Meaning Value Explanation
eventTxName(6) Designation of event txAmpPowerOn(84) Amplifier ON/OFF
eventTxMask(7) Message for event disable(2) No alarm is sent
eventTxPriority(8) Priority for event Value freely selectable
by customer
Default setting when
supplied: 1
eventTxEvent(9) Current status of
amplifier
active(1)
(inactive(2))
Amplifier ON
(Amplifier OFF)