Chapter 6 Maintenance
2104.6536.72 - 6.1 - E-1
1 Maintenance Information
1.1 Overview of Maintenance Actions
The transmitter is designed to provide years of operation with little maintenance. Mainte-
nance is restricted to the following actions:
Action For Interval/Comment Described in
Software update Exciter and
amplifier
– When available
– Recommended for perfor-
mance improvement or when
adding options
In this chapter
Fan exchange Exciter Every 40000 operating hours R&S SX801 manual,
"Maintenance" chap-
ter
Fan exchange Amplifier – If T
intake air
= 25 °C: Every
60000 operating hours
–If T
intake air
= 45 °C: Every
35000 operating hours
R&S VH8001Cx man-
ual, "Service" chapter
Replacement of
fan mat (option)
Exciter When required R&S SX801 manual,
"Maintenance" chap-
ter
Backup of param-
eter data
Exciter Recommended R&S SX801 manual,
"Maintenance" chap-
ter
Adjustment of I/Q
modulator
Exciter If necessary R&S SX801 manual,
"Maintenance" chap-
ter