Chapter 3 Installation
2104.6536.72 - 3.5 - E-1
8) COMBINER POWER OUT (X35, RF power output 600 W after combiner; extended amplifier only)
9) AMPL CONTROL (X11, amplifier control with connection to the CAN bus)
10) AUX DET 1 (X6, input auxiliary detector 1; base amplifier only)
11) AUX DET 2 (X7, input auxiliary detector 2; base amplifier only)
12) FAN 1 (X22, connection for fan 1)
13) FAN 2 (X23, connection for fan 2)
14) EXT FAN SUPPLY (X24, emergency power supply for fans; extended amplifier)
15) Grounding pin
Designation No. Type Connector / function
MAINS X1 M3E+6X+PE; connector
from Schaltbau
AC supply input, optionally DC
POWER OUT X2 N, female RF power output to filter or combiner in
extended amplifier, depending on con-
figuration
AUX DET 1 X6 SMA, female RF input from auxiliary detector 1; for
signal from external directional coupler
test point, e.g. forward power down-
stream of channel filter; base amplifier
only
AUX DET 2 X7 SMA, female RF input from auxiliary detector 2; for
signal from external directional coupler
test point, e.g. reflected power down-
stream of channel filter; base amplifier
only
RF IN 1 X10 SMA, female Standard RF input for signal from
exciter A
AMPL CONTROL X11 D-Sub, 15-pin, male con-
nector
Interface for controlling the amplifier
using built-in CAN bus
EXT AMP OUT X15 SMA, female RF output for controlling the extended
amplifier; base amplifier only
FAN 1 X22 Molex, 4-pin, male con-
nector
Power supply, fan 1
FAN 2 X23 Molex, 4-pin, male con-
nector
Power supply, fan 2
EXT FAN
SUPPLY
X24 Molex, 4-pin, male con-
nector
Emergency power supply from base
amplifier to extended amplifier fan in
event of power failure in extended
amplifier
a)
BASE AMP IN X34 N, female Combiner RF input 1, for signal from
base amplifier; in extended amplifier
only
COMBINER
POWER OUT
X35 7/16, female connector RF power output after combiner; in
extended amplifier only
EXT AMP IN X36 N, female Combiner RF input 2, for signal from
extended amplifier; in extended ampli-
fier only

Table of Contents