Chapter 3 Installation
2104.6536.72 - 3.10 - E-1
AC supply voltage 100 V /
120 V
b)
– / 30 A – / 30 A – / 60 A – / 60 A
Recommend line cross-section
in power system (VDE/UL)
System voltage 230 V 2.5 mm
2
/
AWG = 14
2.5 mm
2
/
AWG = 14
6 mm
2
/
AWG = 10
6 mm
2
/
AWG = 10
System voltage 100 V / 120 V AWG = 10 AWG = 10 AWG = 6 AWG = 6
Power dissipation output maxi-
mum for DVB-T
1.2 kW 1.5 kW 2.3 kW 2.9 kW
RF output N N 7/16 7/16
a) Special note for fuses R&S SCV8202E (400 W) and R&S SCV8302E (600 W): In case only 16 A fused cir-
cuits are available, the base and extended amplifiers must be supplied independently (separate 16 A / 15 A
fused circuits).
b) only with option 2104.9570
Transmitter type SCV8201E SCV8301E SCV8202E SCV8302E