4) Operating limits
Safety notes See Fig. 4.
Readings of EGT The exhaust gas temperatures (EGT) have to measured at the initial
engine installation in an aircraft and must be verified in the course of test
flights.
Readings of EGT taken approx. 100 mm (3.93 in) from exhaust flange
connections.
Graphic Readings of EGT
Fig. 4
07131
Non-compliance can result in serious injuries or death!
The exhaust system must be designed and built such
that the permissible operating temperatures are main-
tained and the max. exhaust gas temperatures are not
exceeded.
The performance specifications relate to ISA (15 °C)
(59 °F)) conditions and are only achieved if the engine
is equipped with an unmodified GENUINE-
ROTAX exhaust system and airbox.