EasyManuals Logo

Satec PM130E User Manual

Default Icon
161 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #127 background imageLoading...
Page #127 background image
Chapter 8 Retrieving A N D S T O R I N G F I L E S
Using T H E U P L O A D S C H E D U L E R
PM130 PLUS Powermeter Series 127
5. Select a daily, weekly or monthly schedule, and adjust the start time.
If you wish to upload data periodically in predefined intervals, click
on Periodic and define the time period in hours and minutes.
6. Select the number of attempts to upload data in the event of
temporary communication problems or unavailability of your device,
and the delay between attempts in minutes and seconds.
7. If you wish to use the schedule to synchronize the device clock with
your PC, check the RTC Synchronization Enable box. If your
device is password protected by a communications password, type in
the password you set in the device to allow PAS to update the clock.
8. Click on the Select Logs button, check the boxes for logs you want
to upload on a schedule, and then click OK.
9. Check the Enabled box at left to activate a schedule for the device.
10. Click Close to store your schedule.
To keep the Upload Scheduler running, the On-line button
on the PAS
toolbar must be checked all the time. If you uncheck it, the scheduler
stops operations. This does not cause loss of data, since the scheduler will
resume operations when you check this button again.
Suspending the Scheduler
To suspend the Upload Scheduler, check the Suspend Scheduler box at
right. To activate the Upload Scheduler, leave this box unchecked.
Running the Scheduler on Demand
You can run the scheduler at any time outside the schedule by checking
the Start Now box at right. This is a one-time action. After uploading is
completed, the Upload Scheduler un-checks this box automatically.
Reviewing Upload Problems
When the Upload Scheduler fails to retrieve data from the device, or some
data is missing, or another problem occurs, it puts an error message to
the log file. To review this file, select System Log from the View menu.

Table of Contents

Other manuals for Satec PM130E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Satec PM130E and is the answer not in the manual?

Satec PM130E Specifications

General IconGeneral
BrandSatec
ModelPM130E
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals