Clear messaging on alarm clearing – clearing the alarm will automatically cancel
messaging about this alarm, if the user clearing the alarm has the TELEPHONE MESSAGING
CLEARING
right.
Service message after tamper alarm – this option is active, if the TROUBLE MEMORY UNTIL
REVIEW
option is enabled. Information on the tamper alarm can only be cleared from the
troubles memory by using the service code. In the LCD keypad, the " System tamper, call
service" message will be displayed after the tamper alarm (unless the alarm messages are
displayed). The message will no longer be displayed after the troubles memory is reset by
the service.
Warning alarm – the system includes an activated warning alarm feature, whose purpose is
to delay the loud signaling and reporting, if any mistakes are made when entering the
protected facility. The warning alarm is not monitored. It can be signaled on the keypad,
proximity card reader or outputs with the function 2. INTERNAL SIREN. The warning alarm is
triggered by zones with the following reaction types:
– 0. E
NTRY/EXIT or 1. ENTRY/EXIT FINAL – unless the system is disarmed before completion
of the E
NTRY DELAY countdown;
– 2. ENTRY/EXIT ROUTE – if it is violated during the ENTRY DELAY countdown, and the
system is not disarmed before completion of the DELAY TIME countdown;
– 3. INSTANT – if it is violated during the ENTRY DELAY countdown.
The warning alarm lasts 30 seconds. Unless the alarm system is disarmed during this
time, the alarm will be triggered by the zone.
Warning alarm on internal sirens – this option is active, if the WARNING ALARM option is
enabled. The warning alarm will be signaled on outputs with the 2. INTERNAL SIREN
function.
Tamper alarm always audible – the tamper alarm will be signaled always on outputs with
the functions 1. EXTERNAL SIREN and 2. INTERNAL SIREN (in armed mode only if the option
is disabled). Also, lack of the expander is always saved in the event log as a tamper
alarm. If the option is disabled, lack of the expander will be saved in the event log:
– as a trouble, if the partition to which the expander is assigned, is disarmed (but the
keypad will signal tamper alarm anyway);
– as a tamper alarm, if the partition is armed.
Tamper alarm on internal sirens – the tamper alarm will be signaled always on outputs with
the function 2. INTERNAL SIREN (in armed mode only if the option is disabled). Additionally,
the output will always signal lack of the expander (also when the event is logged as
a trouble – see: option T
AMPER ALARM ALWAYS AUDIBLE).
Block after 3 unknown codes/cards – after entering an invalid code / reading in an invalid
card three times, the keypad / reader will be blocked for 90 seconds. After this period of
time has expired, each subsequent entry of an invalid code / read-in of an invalid card will
block the keypad / reader at once. The counter of invalid codes / cards will be reset after a
correct code is used.
Service Mode from RESET pins – it is possible to start the service mode and local
programming "from pins" (on the keypad this option is available in the submenu
0. S
RVMOD CONFIG (XSERVICE MODE X0. SRVMOD CONFIG X6. SRVMOD OPT. XSRVMOD VIA
RESET)).
Limit storing "Test transmission" events – if the "Test transmission" events directly follow
one another, they are only written to the event log 3 times. Information on sending next
test transmissions is not recorded. Any other event occurring in the system will reset the
counter of "Test transmission" events, i.e. it will be possible to log next three consecutive
test transmissions.