22 Programming Manual SATEL
3. Global Parameters
3.1 Global options
Reporting – TELEPHONE – the control panel can send event codes to the monitoring
station by means of the telephone line.
Telephone messaging – the control panel can notify about the occurrence of specific events
by means of voice messages or SMS messages using the telephone links.
Answering – modem – an option of external initiation of the communication between
modem and control panel.
Double call – the control panel must be called twice for the modem communication to be
established. The first time you must wait for the preprogrammed number of rings and hang
up. Then you must call back within three minutes and the control panel will answer the call
immediately. This solution makes it possible to connect after the control panel some
additional devices which will be activated after a preset number of rings (e.g. answering
machine, fax, etc. ).
Tone dialing – the control panel will tone dial the telephone numbers (pulse dial, if this
option is disabled).
Pulse 1/1.5 (off 1/2) – this option applies to dialing the telephone numbers by using the pulse
mode. Before you enable it, make yourself familiar with the valid standard of pulse dialing.
No dial tone test – the control panel will not perform the test for dial tone before dialing the
number and will start dialing the number 5 seconds after going "off hook". This makes it
possible for the control panel to dial the number when some non-standard tones occur on
the telephone line after going off hook (e.g. interrupted tone). When this option is disabled,
the control panel will start dialing the number 3 seconds after going off hook, provided that
the dial tone is present.
No answer tone test – in case of notifying by means of voice messages, the control
panel will not perform the test for "off hook" condition. The voice message will be
played back 15 seconds after completion of the number dialing. In case of monitoring,
the control panel will ignore any signals (including the busy tone) received from the
telephone exchange after dialing the telephone number, and will wait for the
handshake from the monitoring station. Enable this option if, after dialing the number,
non-standard signals are received from the telephone exchange or in case of very
poor quality connections.
Store key fob events – using the key fob is written into the events log.
Trouble memory until review – the trouble memory is being signaled until it is cleared
(clearing the trouble memory is possible when you quit the TROUBLES user function).
Serial data on OUT 3/4 – OUT3 and OUT4 outputs send the system status data (zone
alarms, fire alarms, troubles, armed modes, etc.) and do not execute any other
programmed functions. The outputs may be used to control the NR2-DSC radio monitoring
transmitter (NEMROD system – PC-16 OUT format), made by NOKTON.
OUT 3/4 data extended mode – this option is active, if the SERIAL DATA ON OUT 3/4 option is
enabled. The OUT3 and OUT4 outputs will send the system status data in the form of
frames (PC-16 OUT UA format).
Arming/Disarming/Clearing signaling from zones only – outputs with the functions
1. EXTERNAL SIREN and 2. INTERNAL SIREN with enabled ARMING/DISARMING/CLEARING
SIGNALING
option will signal arming and disarming, as well as alarm clearing executed by
means of zones (the arming and disarming, as well as alarm clearing by means of keypad,
proximity card reader or timer will not be signaled).