SATEL VERSA 51
LED G / LED Y – reaction of the partition after removal of the card from the reader, when the
green / yellow LED is lit. One of the three armed modes can be enabled in the partition,
the partition can be disarmed or its status may remain unchanged.
Note: In the DLOADX program, the type of partition reaction after removal of the card from the
reader face is to be programmed by clicking in table on the field corresponding to the
selected partition. A double click on the field will change the icon displayed in it. In the
LCD keypad, the type of partition reaction should be selected from the list.
Fig. 15. Programming the proximity card reader settings in the DLOADX program (an example
of configuration).
Reader options
– Alarm signaling – the reader will be audibly signaling alarms during the KEYPAD’S
ALARM TIME
.
– Alarm signaling until canceled – the reader will be audibly signaling alarms until they
are cleared.
– 3 wrong cards alarm – reading the unknown card code three times by the reader will
trigger alarm.
– Signaling entry delay – the reader will be audibly signaling the entry delay countdown.
– Signaling exit delay – the reader will be audibly signaling the exit delay and auto-arm
delay countdown.
– Signaling card (hardware) – the reader will signal readout of the card code with
a single beep (the code will be sent to the control panel after the card is removed and
only then the reader will audibly signal its reaction to the read code).
8. Timers
4 timers can be programmed in the VERSA control panels. Using the timers, it is possible to
control the armed mode of partitions and the outputs 15. CONTROLLED. The timer compares
time with the control panel clock and executes the selected function at a set time. In the LCD
keypad, only the timer names can be programmed in the service mode. The other
parameters are programmed by means of functions available in the user menu ([CODE]
X6. SETTINGS X3. TIMERS). In the DLOADX program, all parameters can be
programmed in the "Versa – Timers" window.
The following can be programmed for each timer:
– individual name (up to 16 characters);