SATEL VERSA 43
7.2.1 Parameters of ABAX system wireless devices
Filter – the number of consecutive response periods, during which establishing
communication with the device was unsuccessful, for the loss of communication with the
device to be reported. You can enter values from 0 to 50. Entering the digit 0 will disable
the check for device availability in the system.
Always active – option available in most wireless detectors. It enables the detector to be
permanently switched over to the active mode (see: Section WIRELESS DETECTORS
GENERAL PROGRAMMING RULES
).
Note: The ALWAYS ACTIVE option does not have to be enabled for the wireless detectors
assigned to 24-hr zones, because those zones are active at all times.
Configuration – some of the wireless devices provide additional parameters and options,
which can be configured by radio:
APD-100 – wireless passive infrared detector. Sensitivity is to be programmed. In case
of detectors with firmware version 2.01, determine additionally whether the option of
immunity to pets up to 15 kg in weight should be enabled.
APMD-150 – wireless dual motion detector. The following is to be programmed:
sensitivity of infrared path;
sensitivity of microwave path;
test mode operation.
AMD-100 and AMD-101 – wireless magnetic detectors with an additional input. The
AMD-101 detector takes up 2 zones in the system (the first zone – magnetic detector,
the other zone – additional input of the detector). For detectors with electronics version
3.5 D or later, it should be determined which of the two reed switches on the electronics
board is to be active.
AGD-100 – wireless glass break detector. Sensitivity of the high-frequency channel is to
be programmed.
AVD-100 – wireless vibration detector and magnetic contact. The detector occupies 2
zones in the system (the first zone – magnetic contact, the other zone – vibration
detector). Determine for the magnetic contact which of the two reed switches on the
electronics board is to be active. Program the following for the vibration detector:
sensitivity. Sensing a single vibration meeting the sensitivity criterion will cause
violation of the detector.
number of pulses. Registering the predefined number of vibrations within 30 seconds
will cause violation of the detector. All vibrations count (they do not have to meet the
sensitivity criterion). For the value 0, the pulses are not counted.
Note: Parameters are being independently analyzed. As a result, the detector can
signal violation after registering a strong single vibration, caused by a powerful
impact, as well as after a few slight vibrations, caused by a series of weak
strikes.
ASD-100 – wireless smoke and heat detector. The following is to be programmed:
operating mode of the heat detector (you can disable the detector or select the
detection class in accordance with Standard EN 54-5);
operating mode of the buzzer;
duration of alarm signaling by buzzer/LED.
ASP-105 – wireless triggered outdoor siren. The following is to be programmed:
type of acoustic signaling;
duration of acoustic signaling.