32 Programming Manual SATEL
5.5 Zone options
Alarm on exit delay end – if the zone is violated at the moment of ending the exit
delay countdown, it will trigger an alarm (if this option is disabled, the zone will
only trigger the alarm when the status changes from normal to violation during the
armed mode).
Priority – arming is impossible when the zone is violated.
Bypass disabled – user cannot bypass the zone using the BYPASSES function (this restriction
does not apply to the service).
Active in night arm – the zone is armed when the night armed mode is activated.
Active in day arm – the zone is armed when the day armed mode is activated.
Power-up delay – the zone is bypassed for 120 seconds after power supply is turned on
(this will prevent triggering false alarms e.g. during start-up of the control panel).
Warning in partial arming – option for the zones which are armed when the day or
night armed mode is activated in the partition. Violation of the zone will not
immediately trigger the burglary alarm but the warning alarm which is not monitored.
It may be signaled on the keypad, proximity card reader or on the output with
2. INTERNAL SIREN function. The warning alarm at partial armed mode is signaled
during the WARNING TIME (see: Section PARTITION PARAMETERS). If the partition is not
disarmed before expiry of the warning time, the zone will trigger the burglary alarm.
Note: Warning alarm in the partial armed mode will work irrespective of the WARNING ALARM
global option, which refers to the delay of loud signaling and monitoring if any mistakes
are made when entering into the protected facility.
Warning on internal sirens – warning alarm in the partial armed mode, is signaled on the
output with the 2. INTERNAL SIREN function.
Auto-reset 3 the zone can trigger up to 3 alarms. As long as the alarm is not cleared
or the partition is not armed/disarmed, violations of the zone will not trigger any alarm.
Auto-reset 1 the zone can trigger only 1 alarm. As long as the alarm is not cleared
or the partition is not armed/disarmed, violations of the zone will not trigger any alarm.
Note: If the A
UTO-RESET 3 and AUTO-RESET 1 options are enabled at the same time, the
A
UTO-RESET 3 option will have priority.
Clearing Autoreset – the alarm counters for zones for which the A
UTO-RESET 3 or AUTO-
RESET 1 option is enabled will be automatically reset at midnight (violations of these zones
will be able to trigger alarms again).
Armed if one partition armed – the option refers to the zones which are assigned to both
partitions. The zone is armed when one of the partitions is armed. Unless this option is
disabled, the zone is armed when both partitions are armed.
Blocks verification – an option for the reaction types 0. ENTRY/EXIT, 1. ENTRY/EXIT FINAL and
17. SHUNT LOCK. The zone will block alarm verification in the partition:
after the zone violation – the reaction types 0. ENTRY/EXIT and 1. ENTRY/EXIT FINAL, and
also the reaction type 17. SHUNT LOCK, when the RESTORE DISABLES VERIFICATION option
is not enabled;
after the zone restore – the reaction type 17. SHUNT LOCK, when the RESTORE DISABLES
VERIFICATION
option is enabled.
In case of the reaction type 17. S
HUNT LOCK, the zone will disarm the system when the
BLOCKS VERIFICATION option is not enabled.
Restore disarms – an option for the reaction type 17. SHUNT LOCK. It is active, if the
BLOCKS VERIFICATION option is not enabled. The zone restore will disarm the partition