SATEL VERSA 33
to which the zone belongs, and the zone violation will shorten the exit delay time. If
the RESTORE DISARMS option is not enabled, the zone violation will disarm the
partition, and zone restore will shorten the exit delay time.
Restore disables verification – an option for the 17. SHUNT LOCK reaction type. It is active, if
the BLOCKS VERIFICATION option is enabled. The zone restore will blocks verification in the
partition to which the zone belongs, and the zone violation will shorten the exit delay time.
If the option RESTORE DISABLES VERIFICATION is not enabled, the zone violation will blocks
verification, and the zone restore will shorten the exit delay time.
Alarm clearing – an option for the 13. ARM/DISARM and 15. DISARMING reaction types.
Together with disarming, the alarm is cleared (except for the tamper alarms). Violation of
the zone with 15. DISARMING type of reaction will also clear the alarm, when the system is
not armed.
Write violations to event log – an option for the 12: NO ALARM ACTION reaction type.
Violation of the zone is saved into the event log (the way of saving the event depends on
the K
EYBOX CONTROL option).
Store event only if armed – an option for the reaction type 12: N
O ALARM ACTION. It is active
when the WRITE VIOLATIONS TO EVENT LOG option is enabled. Zone violations are saved in
the event log when the partition to which the zone belongs is armed.
Keybox control – an option for the reaction type 12: NO ALARM ACTION. It is active when the
WRITE VIOLATIONS TO EVENT LOG option is enabled. Violation of the zone will result in logging
an event which informs that the keybox is open. The event code is sent to the monitoring
station. If this option is disabled, an event will be logged informing about zone violation,
which will not be reported.
LED
Name displayed on
LCD keypad
Options
Reaction
type
1
Al. on exit end Alarm on exit delay end 0-11
2
Priority Priority all
3
Bypass disabled Bypass disabled all
4
Active night arm Active in night arm 0-4
5
Active day arm Active in day arm 0-4
6
Power up delay Power-up delay all
7
Warn. in part. arm Warning in partial arming 0-4
8
Warn. on int. sir. Warning on internal sirens 0-4
9
Auto-bypass 3 Auto-reset 3 0-10
10
Auto-bypass 1 Auto-reset 1 0-10
11
Autobypass reset Clearing Autoreset 0-10
Armed if one partition armed 0-4
12
Arm.with one p.
Keybox control
12
Blocks verification 0, 1, 17
13
Disable verific.
Write violations to event log
12
Restore disarms 17
Restore disables verification 17
Store event only if armed 12
14
Finish exit time
Alarm clearing 13, 15
Table 5. The method of presenting zone options on keypads. In graphic mode, the options in
the LCD keypad are numbered in the same way as in the LED keypad.