40 Programming Manual SATEL
7.1 VERSA-LCD-GR / VERSA-LED-GR keypad
Signaling CHIME from zones – a list of zones which, when violated, will generate chime
signal in the keypad.
Date/Time format – display mode for time and date.
LCD backlight – display backlight mode in the VERSA-LCD-GR keypad.
Keys backlight – backlight mode for the keys.
Auto-backlight – automatic illumination switch-on mode for the keys (in VERSA-LCD-GR
keypad, also for the display).
Sounder volume – control of the loudness level of sounds generated in the keypad.
Keypad options
Signal entry delay – the keypad will acoustically signal the entry delay
countdown.
Signal exit delay – the keypad will acoustically signal the exit delay
countdown.
Signal alarms – the keypad will acoustically signal alarms. Duration of signaling is
determined by the KEYPADS ALARM TIME (see: GLOBAL TIMES).
Quick arming – Partition 1 – quick arming is possible in partition 1 (see: USER
MANUAL).
Quick arming – Partition 2 – quick arming is possible in partition 2 (see: USER
MANUAL).
Key sound – keystrokes on keypad are acoustically signaled.
Signal trouble in partially armed – the LED will be signaling trouble until both
partitions are fully armed (if this option is disabled, activation of any armed mode in any
partition will disable trouble signaling in the keypad).
Show code entering – the keypad will inform about a code being entered:
VERSA-LCD-GR – entering the code is shown by means of asterisks in the lower line of
the LCD display;
VERSA-LED-GR – entering the code is shown by means of LEDs in the lower line of
LEDs.
Chime ON/OFF – the chime signal can be enabled/disabled by means of the
key
(the key is to be pressed for about 3 seconds).
Quick control – the outputs can be quickly controlled by means of numerical keys. If
any 15. C
ONTROLLED output is assigned to the key (see: Section QUICK CONTROL OF
OUTPUTS
), press that key and confirm using to activate the output, and press the
same key and confirm using – to deactivate it.
Signal new trouble – the keypad will acoustically signal occurrence of a new trouble, if
the TROUBLE MEMORY UNTIL REVIEW option is enabled (see: Section GLOBAL OPTIONS).
Auto-arm delay countdown – the keypad will acoustically signal the auto-arm delay
countdown.
Arm mode review – press and hold down the key for about 3 seconds to display
information on the partition status (whether or not they are armed and what is their
armed mode – see: USER MANUAL).
Alarms – options regarding the alarms triggered from keypad (the list of options in keypad
includes also those for displaying alarm messages on the VERSA-LCD-GR keypad, as
described below):
Fire alarm – press the key for approx. 3 seconds to trigger the fire alarm.

Table of Contents