26 Programming Manual SATEL
Notes:
• The exit delay countdown can be terminated by means of the zones type 1. ENTRY/EXIT
FINAL
or 16. EXIT DELAY TERMINATOR. All zones in the partition will be armed before expiry
of the programmed exit delay time.
• Using the keypad, you can arm the system without the exit delay, if the hold down the
key which ends the arming sequence ( , , or ) for approx. 3
seconds.
Infinite exit delay – the partition exit delay time can only be ended by means of the zones
with reaction type 1. ENTRY/EXIT FINAL, 16. EXIT DELAY TERMINATOR or 17. SHUNT LOCK. If
the exit delay countdown is not completed, the armed mode will not be activated (only the
zones with reaction type 3. INSTANT will be armed).
Entry delay – the time counted from the moment of entry into the protected area which
enables the partition to be disarmed before triggering an alarm. This parameter
applies to the zones type 0. ENTRY/EXIT and 1. ENTRY/EXIT FINAL. The delay
programmed for the partition is taken into account in case of the zones for which the
value 0 has been individually programmed. The delay is programmed in seconds. Up
to 255 seconds can be programmed. If the value 0 is programmed, the zone will act
as an instant one.
Warning time – the time of warning alarm signaling for the partial armed mode (see: zone
option WARNING IN PARTIAL ARMING). The time is programmed in seconds. Up to 255
seconds can be programmed. If the value 0 is programmed, the WARNING TIME will be 30
seconds. After expiry of the WARNING TIME, unless the partition is disarmed, the burglary
alarm will be triggered.
Note: The WARNING TIME parameter does not apply to the time of signaling the warning alarm
which is generated when mistakes are made when entering into the protected object
(see: WARNING ALARM global option).
Verification time – programming a value different from 0 means activating the alarm
verification feature in the partition. Subject to verification are alarms from zones with
reaction type from 0 to 5. The VERIFICATION TIME runs from the moment of alarm being
triggered by such a zone. If during the VERIFICATION TIME an alarm is triggered by another
zone in the partition, with the reaction type from 0 to 5, the control panel will report
a verified alarm. The time is programmed in minutes. Up to 255 minutes can be
programmed.
Timer priority – the timer will always arm / disarm the partition according to the preset times
(if this option is not enabled, the timer will only disarm the partition, if the arming was done
by the timer).
Auto-arming delay – the time counted from the moment when the timer is to arm the
partition, enabling the arming to be deferred. The delay time is programmed in seconds.
Up to 255 seconds can be programmed. Programming the value 0 means that the arming
deferment will be unavailable.
Deferment time – the time by which the user can defer arming by the timer. The time is
programmed in minutes. Up to 255 minutes can be programmed. Programming the value 0
means that the arming deferment will be unavailable.
Simple deferment – the user can defer arming by the timer by pressing the
key twice
during the auto-arm delay time countdown.
Single deferment – the user can only use the simple deferment once, so as to postpone the
arming by timer. Subsequent arming deferments are only possible by using the A
UTO-
ARMING DEFERMENT user function ([CODE] X6. SETTINGS X1. A-ARM DEFER.).