36 Programming Manual SATEL
– output 13. ZONE VIOLATION remains active throughout the time of zone violation,
– output 15. CONTROLLED remains active until another violation of the controlling zone,
disabling of timer or disabling of the output by means of keypad (bistable mode).
Activation: zones – the zones whose status has effect on the output status.
Activation: partition armed mode – the armed modes whose activation in the partition will
activate the output with function 18. ARMED STATUS (the number corresponds to the LED
number in the LED keypad and to the item number in graphic mode in the LCD keypad):
1. Partition 1 – full armed mode
2. Partition 1 – night armed mode
3. Partition 1 – day armed mode
4. Partition 2 – full armed mode
5. Partition 2 – night armed mode
6. Partition 2 – day armed mode
If no armed mode is selected, the output will activate any armed mode is activated.
Activation: troubles – the troubles the occurrence of which will activate the output with
function 19. TROUBLE STATUS (the number corresponds to the LED number in the LED
keypad and to the item number in graphic mode in the LCD keypad):
1. AC loss – control panel mainboard
2. Battery trouble – control panel mainboard
3. Telephone line – no voltage
4. Telephone line – no dial tone
5. OUT1 output trouble
6. OUT2 output trouble
7. KPD output trouble
8. AUX output trouble
9. Reporting trouble – monitoring station 1
10. Reporting trouble – monitoring station 2
11. Wireless system jamming
12. Communication bus short circuit
13. Clock loss
14. RAM memory error
15. Mainboard TMP open
16. Zones – tamper
17. Zones – long violation
18. Zones – no violation
19. Zones – masking
20. Wireless device battery low
21. Wireless device communication loss
22. Module tamper
23. No presence (module)
24. AC loss (module)
25. Battery trouble (module)
26. Power output overload (module)
27. Low battery (key fobs)
28. Module restart