54 Programming Manual SATEL
alarms from zones. For each zone, the number of alarms can be individually limited by
means of the AUTO-RESET 3 or AUTO-RESET 1 option.
Report module restarts – in case of sending event codes in Contact ID or SIA format,
the monitoring station is informed about module restarts.
Restore after bell – the zone restore code will only be sent to the monitoring station
after the alarm signaling ends. If a few outputs are signaling alarm, the zone restore
code will be sent when one of them stops signaling the alarm.
Restore after disarm – the zone restore code will only be sent to the monitoring station
after disarming the partition to which the zone belongs.
Station 1 / Station 2
Reporting format – format in which event codes are sent to the monitoring station. The
VERSA series control panels allow to chose from several formats, including Contact
ID and SIA.
Telephone number – telephone number of the monitoring station.
Repetitions – the number of attempts to establish connection with the monitoring
station after which, if there is no connection (busy number, no answer from the
station, etc.), the control panel will suspend reporting. Up to 31 retries can be
programmed. Programming the value 0 means that monitoring will be suspended
after 8 attempts.
Suspend time – the time for which reporting is suspended, after making the
programmed number of attempts to establish connection with the monitoring station.
The control panel will resume the attempt of establishing telephone connection with
the monitoring station after this time expires or a next, new event occurs. Up to 30
minutes can be programmed. Programming the value 0 means that an attempt to
establish telephone connection with the monitoring station will only be taken after
occurrence of a new event in the system.
Identifiers – event codes are sent to the monitoring station in one of the four identifiers:
identifier 1 – events from zones (alarms, tampers, troubles);
identifier 2 – alarms triggered from keypad, arming/disarming by means of zones,
quick arming, loss of communication with wireless devices, as well as expander
troubles and tampers;
identifier 3 – arming/disarming and alarm clearing by means of code or proximity
card;
system identifier – power supply troubles, zone bypasses, troubles of control panel
high-current outputs, communication bus trouble, programming related events, etc.
4 hexadecimal characters (digits or letters from A to F) should be programmed for
each identifier. Entering the value 0000 means that events assigned to that identifier
will not be reported. Using the digit 0 in the identifiers is not recommended.
SIA / TELIM prefix – 2 characters which will precede each of the identifiers in case of
the SIA and TELIM formats. Thus an identifier consisting of 6 characters can be
obtained. 2 hexadecimal characters (digits or letters from A to F) can be
programmed. Entering 00 means that the prefix will not be added. Using the digit 0 in
the prefix is not recommended.
Station 1 options / Station 2 options
Longer waiting for initial handshake – the control panel will wait longer for
handshake from the monitoring station in case of sending events in the Ademco
Express, Contact ID or SIA format. Enable this option if the monitoring station sends
a non-standard initial handshake.