SATEL VERSA 15
6.7.4 Arming without delay
The arming without delay means that the delayed zones will act as the instant ones (there will
be no exit or entry delay). To arm without delay, the key corresponding to the selected
arming mode ( , or ) should be pressed and hold for approx. 3 seconds.
6.7.5 Arming under duress
In the event of acting under duress, you can arm the system by one of the aforementioned
methods, but you must use a special duress code, instead of the normal user code. Using the
DURESS code will trigger a silent alarm, which is signaled in no way whatsoever, but the
alarm code will be sent to the monitoring station.
6.7.6 Information about bypassed zones before arming
The installer can program control panel so that in the event of arming by means of the LCD
keypad the users having the INSPECTION right can get information about bypassed zones in
the partition which is to be armed. The information on bypassed zones will not be displayed
in case of the quick arming. The contents of displayed message depends on whether the
user has the ZONE INHIBITION right:
"Bypassed zones 1=Arm 4=Bypasses" – the message is displayed when the user has the
ZONE INHIBITION right. The user can:
– press the key to cancel the arming;
– press the key to proceed with the arming;
– press the key to start the INHIBIT user function (see: ZONE INHIBITING).
"Bypassed zones 1=Arm" – the message is displayed when the user does not have the
ZONE INHIBITION right. The user can:
– press the key to cancel the arming;
– press the key to proceed with the arming;
6.7.7 Denial of arming and forced arming
The installer can program the control panel so that the keypad can signal with one long beep
the denial of arming when:
– in the partition to be armed, at least one zone that must not be violated during arming
(the PRIORITY option has been enabled for the zone by the installer) is violated;
– in the partition to be armed, at least one alarm zone is violated beyond the exit route;
– there is trouble in the system.
The user who uses the LCD keypad and has the INSPECTION right will be informed about the
cause of the denial of arming – the LED will go on and a suitable message will be
displayed (the order of message description corresponds to their priority):
"Zone [zone number] violat." – a zone that must not be violated during arming (zone with
the PRIORITY option enabled) is violated. If several such zones are violated, the
arrow is
flashing on the right side, in the bottom line of the display. The list of violated zones can be
scrolled through by means of the key (down) and the key (up). The user can:
– press the key to cancel the arming;
– press the key to inhibit the violated zone (he must have the ZONE INHIBITION right).
A message will be displayed, prompting the user to confirm the command to inhibit the
zone (pressing the key will inhibit the zone; pressing the key will cancel the
zone inhibition).
Note: If a zone with the PRIORITY option enabled is violated, you must either remove the
cause of the zone violation, or to inhibit the zone for the arming to be possible.