Satel Versa - Disarming And;Or Alarm Clearing in Selected Partition; Disarming And;Or Alarm Clearing under Duress; Viewing the Zones Which Triggered Alarm; Quick Inspection of Partition Status

Satel Versa
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SATEL VERSA 17
Note: If no partition is armed or reporting alarm, you can enter the code and press the
key to start the arming procedure. It is recommended to use the key for
disarming/alarm clearing.
6.8.2 Disarming and/or alarm clearing in selected partition
1. Indicate partition which is to be disarmed and/or where alarm is to be cleared (press one
of the keys: - partition 1; - partition 2).
2. Press the key. Backlight of the keys will start blinking, which indicates that the code
must be entered.
3. Enter the code.
4. Press the or key. Disarming and/or alarm clearing in the selected partition
should be confirmed by 3 short beeps.
6.8.3 Disarming and/or alarm clearing under duress
In the event of acting under duress, you can disarm the system and/or clear the alarm by one
of the aforementioned methods, but you must use a special duress code, instead of the
normal user code. Using the DURESS code will trigger a silent alarm, which is signaled in
now way whatsoever, but the alarm code will be sent to the monitoring station.
6.8.4 Viewing the zones which triggered alarm
Immediately after the alarm is cleared you can check which zones caused the alarm (this
does not apply to the control panel TMP zone).
In the LCD keypad, enter the code first, and then press the key. The "View cleared
zones? 1=Yes" message will appear on the display. Press the key to display a list of
zones which triggered the alarm. After having viewed the list, press the key to display
the user menu. The message that prompts to view the list of zones which triggered the alarm
will be displayed until viewing the list or arming.
In the LED keypad, you must first enter the code, and then press successively the
keys (the function is only available until viewing the list or arming). A blinking
LED means that alarm was triggered by the zone with the number corresponding to the LED
number.
6.9 Quick inspection of partition status
If such an option is allowed for by the installer, press and hold down the key for
approx. 3 seconds to display information on the partition status (if and what armed mode is
activated). When the information on partition status is displayed, the
LED is lit in the
keypad.
The LCD keypad provides information on the partition status by means of the display. The
message on the status of first partition is displayed in the upper line, and the message on the
status of second partition in the lower line.
In the LED keypad, information on the partition status is provided by means of LEDs 1-3
(partition 1 status) and LEDs 16-18 (partition 2 status):
none of the LEDs is ON partition is disarmed;
LED 1 is ON full armed mode in partition 1;
LED 2 is ON night armed mode in partition 1;
LED 3 is ON day armed mode in partition 1;
LED 16 is ON full armed mode in partition 2;
LED 17 is ON night armed mode in partition 2;
LED 18 is ON day armed mode in partition 2.