SATEL VERSA 47
8.1 Denial of arming and forced arming by means of keyfob
Note: The information given below is not applicable, if the keyfob button controls arming
zone.
The installer can program the control panel so that arming by means of keyfob is not possible
when:
in the partition to be armed, at least one zone that must not be violated during arming
(the PRIORITY option has been enabled for the zone by the installer) is violated;
in the partition to be armed, at least one alarm zone is violated beyond the exit route;
there is trouble in the system;
there is low battery in the keyfob.
In such a situation, to arm the system, you must either eliminate the cause that prevents
arming, or force the arming. The forced arming by means of keyfob is possible, if the user
has access to the LCD keypad. After denial of arming by the control panel, you should come
up to the LCD keypad, enter the code and confirm with the key. A message will appear
on the display indicating why the arming has been denied. If the message includes the
"1=Ok" phrase, you can press the key to force the arming. Press again the keyfob
button to which the arming function is assigned to start the forced arming procedure.
8.2 Failure of the arming procedure initiated from keyfob
Note: The information given below is not applicable, if the keyfob button controls arming
zone.
The alarm system can be configured by the installer so that the arming procedure may fail
even if it has been started. The arming will fail, if at moment of completion of the exit delay
countdown:
a zone with enabled PRIORITY option or an alarm zone beyond the exit route is violated
in the partition,
there is a trouble in the system.
Note: In the event of forced arming the control panel will ignore violations and troubles
reported before the moment of starting the arming procedure.
9. Operating the Alarm System by Telephone
If the INT-VG voice module is connected to the control panel, a user with the INT-VG ACCESS
right can remotely operate the alarm system by telephone. The installer can also make the
system operating option dependent on the partition status (the operation will be possible only
when the selected partitions are armed). Using the phone, you can:
get information on alarms, troubles, as well as status of partitions, zones and outputs;
run a macro (i.e. a sequence of actions to be done by the control panel, as defined by the
installer);
arm/disarm;
clear alarm;
clear trouble memory;
bypass/unbypass zone;
enable/disable a 15. CONTROLLED function output.