42 User Manual SATEL
6.26.1 Service code access rules
With the SERVICE ACCESS function, the user can define the rules of access to the alarm
system by persons using the service code.
Permanent accessthe service code has unlimited access to the alarm system.
Edit usersthe persons using the service code can add, edit and remove users.
Arming/Disarming/Clearing/Bypassing the service code can arm and disarm the system,
clear alarms, and bypass zones (inhibit or isolate).
Access time the function is available when the PERMANENT ACCESS option is disabled. It
defines the period of time during which the service code has access to the alarm system.
The time is programmed in hours. If value 0 is programmed, the service code has no
access to the system. The time countdown runs from the moment of exiting the ACCESS
TIME
function.
Note: If the alarm system is to meet requirements of the EN 50131 standard for Grade 2, the
service code access should be time limited.
Programming the service code access rules in LCD keypad
Enter the user menu and press in turn the keys for the function name
to appear in the upper line of the display, and the list of available options in the lower
line. Use the and keys to scroll through the list of options. Shown in the top
right corner of the display is an additional symbol:
option is enabled;
option is disabled.
Press any number key to enable/disable the option. Press the or key to
switch over the keypad to graphic mode. The current status of all options is on the
display by means of the and symbols. Use the key to move the cursor to the
right, and the key to move the cursor the left. To enable/disable the option, move
the cursor over the selected option and press any number key. After the or
key is pressed, the keypad returns to the text mode. To save the changes made, press
the key.
If the PERMANENT ACCESS option has been disabled by the user, it is possible to define
the service code access time. To do so, enter the user menu again, and then press in
turn the keys. The number of hours during which the service code
will still have access to the alarm system will be displayed. Using the number keys,
enter a number from the 0 to 255 range and press key.
Programming the service code access rules in LED keypad
Enter the user menu and press in turn the keys. The lit LEDs indicate
which options are enabled. The blinking LED shows where the cursor is at the moment.
The key moves the cursor to the right, and the key to the left. To
enable/disable the option, move the cursor over the selected option and press any
number key.
If the PERMANENT ACCESS option has been disabled by the user, it is possible to define
the service code access time. To do so, enter the user menu again, and then press in
turn the keys. The number of hours during which the service code
will still have access to the alarm system will be presented in binary format on the LEDs
(see: page 20, Table 1). Using the number keys, enter a number from the 0 to 255
range and press key.