SATEL VERSA 31
– zone is inhibited;
– zone is isolated.
Pressing any number key will change the displayed symbol to one of the following ones:
– the zone is to be inhibited;
– the zone is to be unbypassed.
Press the or key to switch the keypad over to graphic mode. The current
status of all available zones that can be bypassed/unbypassed is presented on the
display by means of the , and symbols. The key will move the cursor to the
right, and the key to the left. Bypassing/unbypassing a zone is effected in the
same way as in the text mode. Press the or key for the keypad to return to
the text mode.
Termination of the function by pressing the key will bypass/unbypass selected
zones.
LED keypad
Lit LEDs indicate which zones are inhibited or isolated. A rapidly blinking LED shows
where the cursor is at the moment. The key will move the cursor to the right, and
the key to the left. The cursor may only be moved over the LEDs corresponding
to the zones which can be bypassed or unbypassed. To bypass/unbypass a zone, press
any number key – depending on the current status, the LED will go on (the zone is to be
inhibited) or go off (the zone is to be unbypassed). Termination of the function by
pressing the key will bypass/unbypass selected zones.
6.16.2 Zone isolating
The zones can be isolated by users having the ZONE INHIBITION and ZONE ISOLATION rights
(the user must have both authorizations). The isolated zone will remain bypassed until it is
unbypassed by the user.
To start the function that enables the zones to be isolated, enter the user menu and press in
turn the keys. Use the same function to unbypass the zones (irrespective
of whether they are inhibited or isolated). 2 short beeps will confirm entering the function, and
the LED will go on. The procedure differs depending on the type of keypad.
LCD keypad
The manner of indicating the zone status and the procedure are identical to those used
for zone inhibiting. Press a number key to change the currently displayed symbol to:
– the zone is to be isolated;
– the zone is to be unbypassed.
Termination of the function by pressing the key will bypass/unbypass selected
zones.
LED keypad
The manner of indicating the zone status and the procedure are identical to those used
for zone inhibiting.
6.17 Viewing the event log
The function of viewing the event log is only available in the LCD keypad to the user having
the INSPECTION right. To start the function that enables event viewing, enter the user menu
and press in turn the keys. 2 short beeps will confirm entering the function, and
the LED will go on.