Note: In the event of failure of the control panel processor system (HSE), when you have
exited the 7. SYSTEM STATE function by using the key, the "Make VERSA panel
restart? 1=Yes" message will be displayed on the LCD keypad, and the
LED will
start blinking rapidly in the LED keypad. Pressing the key will restart the control
panel and repair the trouble.
6.23.3 Trouble memory and clearing the trouble memory
The installer defines whether the 7. SYSTEM STATE function will only provide information on
the current troubles, or also about those that have already ended. The trouble memory is
signaled in the LCD keypad by blinking "M" letter in the top right corner of the display. In the
LED keypad, a LED designated with number is lit steadily instead of blinking.
When exiting the 7. SYSTEM STATE function (on pressing the key) you can clear the
trouble memory. In the LCD keypad, the "Clear trouble memory? 1=Yes" message will
appear on the display. In the LED keypad, the
LED will start blinking rapidly. Press the
key to clear the trouble memory or press any other key to cancel clearing the trouble
memory.
Note: If the installer has enabled the SERVICE MESSAGE AFTER TAMPER ALARM global option in
the control panel, clearing the tamper alarm memory will only be available to a person
using the service code.
6.24 Output control
The user can operate devices connected to the 15. CONTROLLED type of outputs by means of
keypad. Thus he can e.g. to raise/lower the roller shutters, turn on/off the lighting or heating,
etc. When configuring the system, the installer defines whether the given output will be
activated for a specified time, or remain active until deactivated by user, timer, etc.
6.24.1 Quick control of outputs
The installer may permit the quick control of outputs by means of a selected keypad. In such
a case, the user does not have to enter the code to control operation of the devices
connected to the alarm system outputs.
Quick activation of output
1. Press the number key to which controllable output has been assigned by the
installer.
2. Press the key. 4 short beeps and 1 long beep should confirm activation of the
output.
Quick deactivation of output
1. Press the number key to which controllable output has been assigned by the
installer.
2. Press the key. 3 short beeps should confirm deactivation of the output.
6.24.2 Controlling the outputs by means of function
This method of control is available to users having the CONTROL right. In order to start the
function that enables the control of outputs, enter the user menu and press in turn the
keys. 2 short beeps will confirm entering the function, and the LED will go on.
Depending on the type of keypad, the output status is presented in different ways. To exit the
function, press key.