www.schaerer.comInstallation & commissioning
Programming manual (Customer Program) / V03/05.2012
9 / 56
Technical data
Nominal power * 2200-2200 W
Operating temperature Steam boiler ** Hot water boiler **
Minimum operating temperature (T min.): 130°C 86°C
Maximum operating temperature (T max.) 130°C 102°C
Overpressure Steam boiler ** Hot water boiler **
Working overpressure 2.5 bar 16 bar
Permissible working overpressure (p
max):
16 bar 16 bar
Test overpressure 24 bar 24 bar
Water tank
capacity
2.2 l
Bean hopper
capacity
250 g
Grounds container
capacity
15 – 20 coffee grounds cakes
External dimensions
Width 305 mm
Height 400 mm
Depth 443 mm
Empty weight 15 kg
Continuous noise level (Lpa) ** < 70 dB (A)
We reserve the right to make technical changes.
* For special equipment, see serial plate. The values specied here apply to the basic equipment.
** The A-weighted noise level (slow) and Lpa (impulse) at the operator's' workplace is below 70 dB(A) in every operating mode.