Technical specifications
Multiple sampling
1 time 2 times 3 times 4 times
Application
Number
of
beams
Vertical Horizontal Vertical Horizontal Vertical Vertical
10 10 ms 12 ms 16 ms 18 ms 21 ms 26 ms
15 11 ms 14 ms 17 ms 20 ms 23 ms 29 ms
20 12 ms 15 ms 19 ms 22 ms 25 ms 31 ms
23 13 ms 16 ms 20 ms 23 ms 26 ms 33 ms
25 13 ms 17 ms 20 ms 23 ms 27 ms 34 ms
30 14 ms 18 ms 22 ms 25 ms 29 ms 36 ms
35 15 ms 20 ms 23 ms 27 ms 31 ms 38 ms
38 16 ms 21 ms 24 ms 29 ms 32 ms 40 ms
40 16 ms 21 ms 25 ms 29 ms 33 ms 41 ms
45 17 ms 23 ms 26 ms 31 ms 35 ms 43 ms
50 18 ms 24 ms 27 ms 33 ms 37 ms 46 ms
53 19 ms 25 ms 28 ms 34 ms 38 ms 47 ms
55 19 ms 26 ms 29 ms 35 ms 39 ms 48 ms
60 20 ms 27 ms 30 ms 37 ms 41 ms 51 ms
68 22 ms 29 ms 33 ms 40 ms 44 ms 55 ms
75 23 ms 31 ms 35 ms 43 ms 46 ms 58 ms
80 24 ms 33 ms 36 ms 45 ms 48 ms 61 ms
83 25 ms 34 ms 37 ms 46 ms 50 ms 62 ms
90 26 ms 36 ms 39 ms 49 ms 52 ms 65 ms
100 28 ms 39 ms 42 ms 53 ms 56 ms 70 ms
105 29 ms 40 ms 44 ms 55 ms 58 ms 73 ms
120 32 ms 45 ms 48 ms 61 ms 64 ms 80 ms
135 35 ms 49 ms 52 ms 67 ms 70 ms 87 ms
140 36 ms 51 ms 54 ms 69 ms 72 ms 90 ms
150 38 ms 54 ms 57 ms 72 ms 76 ms 95 ms
160 40 ms 56 ms 60 ms 76 ms 80 ms 100 ms
165 41 ms 58 ms 61 ms 78 ms 82 ms 102 ms
180 44 ms 62 ms 66 ms 84 ms 88 ms 110 ms
22)
22)
Only allowed for horizontal usage. Other usage not allowed as per IEC 61496.
depending on the number of
beams, the application and
the selected multiple
sampling