Chapter 4 Operating Instructions
C4000 Palletizer Std./Adv.
C4000 Fusion
38 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8012249/YT69/2016-02-25
Subject to change without notice
Configurable functions
With reduced resolution the effective resolution of a safety light curtain changes. Tab. 11
shows the effective resolution as a function of the reduced resolution for different physical
resolutions.
Physical
resolution
Reduced
resolution
Effective
resolution
Object sizes that do not result in
shutdown
1 beam 30 mm 10 mm
2 beams 40 mm 20 mm
3 beams 50 mm 30 mm
4 beams 60 mm 40 mm
5 beams 70 mm 50 mm
6 beams 80 mm 60 mm
7 beams 90 mm 70 mm
8 beams 100 mm 80 mm
9 beams 110 mm 90 mm
10 beams 120 mm 100 mm
11 beams 130 mm 110 mm
12 beams 140 mm 120 mm
13 beams 150 mm 130 mm
14 beams 160 mm 140 mm
15 beams 170 mm 150 mm
16 beams 180 mm 160 mm
17 beams 190 mm 170 mm
18 beams 200 mm 180 mm
19 beams 210 mm 190 mm
20 beams 220 mm 200 mm
21 beams 230 mm 210 mm
22 beams 240 mm 220 mm
23 beams 250 mm 230 mm
24 beams 260 mm 240 mm
25 beams 270 mm 250 mm
26 beams 280 mm 260 mm
27 beams 290 mm 270 mm
28 beams 300 mm 280 mm
29 beams 310 mm 290 mm
20 mm
30 beams 320 mm 300 mm
1 beam 50 mm 20 mm
2 beams 70 mm 40 mm
30 mm
3 beams 90 mm 60 mm
1 beam 70 mm 30 mm 40 mm
2 beams 100 mm 60 mm
Tab.
11
:
Effective resolution
as a function of the reduced
resolution