EasyManua.ls Logo

SICK TIC102 master

SICK TIC102 master
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 COMMISSIONING
146
8017768/12AX/2019-05-31|SICK
OPERATING INSTRUCTIONS | TIC
Subject to change without notice
Updating the list
In the toolbar, there are two different options for updating the list of log entries.
If you click on this icon, the list will be updated automatically. New log entries are
continuously added.
Alternatively, you can update the log entries manually with this icon.
Filtering the list according to log entry type
You can filter the list based on the following types: Debug, Info, Warning, and Error.
Click one of the four buttons to activate and deactivate the relevant filter.
You can combine several filters.
Defining the level of detail for “Recorder” log type entries
You can define a different level of detail for the log entries in the Recorder log type.
Support will let you know which level of detail is required to provide further assistance.
1. Switch to editing mode using the Edit default configuration icon.
2. Expand the tree that contains the system functions.
3. Mark a system function or system component in the navigation area (here a 2D LiDAR
sensor) and click the Show Details icon.
4. Select the level of detail advised by Support in the DebugLogLevel parameter. A
distinction is made between Quiet, Normal, Detailed, and Diagnostics detail levels.
5. Click the Start site configuration icon. All system actions are now written to the log file
of the Recorder type with the set level of detail.
Note

Table of Contents