Get Configuration
Ectn.Tems.TemsManagerCmd.exe <connection info> /config=D:\out.temsXml
Retrieves serial number, version number, IP configuration, and NTP configuration and writes the information to an
XML file.
The XML file contains the following elements:
<ConfigurationXml Version="2" RecorderVersion="2.1.4.5">
<RecorderConfig>
<Product>1055102</Product>
<Version>2.1.4.5</Version>
<SerialNumber>12345678</SerialNumber>
<Name>TEMS-1234-5678</Name>
<HardwareId>0123456789AB</HardwareId>
<AcceptanceTest>2002-05-30T09:30:10Z</AcceptanceTest>
<ExternalDhcpEnabled>false</ExternalDhcpEnabled>
<ExternalIpAddress>192.168.10.200</ExternalIpAddress>
<ExternalSubnetMask>255.255.255.0</ExternalSubnetMask>
<ExternalGateway />
<ExternalDnsServers />
<DevicesIpAddress>192.168.20.200</DevicesIpAddress>
<DevicesSubnetMask>255.255.255.0</DevicesSubnetMask>
<DevicesGateway />
<NtpServers>ch.pool.ntp.org</NtpServers>
<ProcessingPoints>8</ProcessingPoints>
<NtpStatusUpdateFrequency>30</NtpStatusUpdateFrequency>
<NtpStatusUpdatePeerMandatory>true</NtpStatusUpdatePeerMandatory>
<NtpStatusUpdateOffsetLimit>0</NtpStatusUpdateOffsetLimit>
<TemsInfoPort>54345</TemsInfoPort>
<TemsInfoMaximalClientCount>10</TemsInfoMaximalClientCount>
</RecorderConfig>
Config Output file where the serialized configuration information is stored.
If no output file is specified, the resulting XML document is printed to the console.
Required
The configuration information was successfully written to the output file.
Timeout, network interruption, …
Invalid output path or access denied