Menus in the WBM
5.3 The Agent menu
SCALANCE X-200
Configuration Manual, 03/2015, C79000-G8976-C285-06
103
Enter the key to be used for signing.
Permitted values for the key: an ASCII string with up to 11 characters or a hexadecimal
string with up to 40 characters.
Select this function to check the signing of the frames.
Syntax of the Command Line Interface
Table 5- 23 Agent Time Client Configuration - CLI\AGENT\TIME>
info Displays information on the time settings of the IE
Enables / disables the time settings of the IE switch.
server [IP address]
Sets the IP address and the port of the server. Administrator only
tinitpoll [1000 -
100000ms]
Specifies the time during two time polls if no time in-
formation has yet been received. You can enter a
value between 1000 and 100000 milliseconds.
Administrator only
tpoll [10 - 100000sec] Specifies the time between two time polls. You can
enter a value between 10 and 100000 seconds.
Administrator only
ttype [P | L | S | N | M] Specifies how the time is set:
- P SNTP Poll
- L SNTP Listen
- S Siemens
- N NTP
Administrator only
time [date] [time] If no parameters are set, this command shows the
time. By entering a time in the format
MM/DD/YYYY hh:mm:ss
Administrator only
offset [+/-] <offset> Specifies the deviation between coordinated universal
Administrator only
Table 5- 24 Agent Time Client Configuration - CLI\AGENT\TIME\NTP>
server <number> <IP> Specifies the IP address of the NTP server indicated
by "number". You can specify IP addresses for a max-
imum of four NTP servers.
Administrator only
initint [1 ... 10000] Specifies the time between two NTP polls if no time
information has yet been received. You can enter a
value between 1 and 10000 milliseconds.
Administrator only
interval [1 ... 160] Specifies the interval between two NTP polls. You can
enter a value between 1 and 160 seconds.
Administrator only