109
PNIO Config
Settings for PROFINET IO
Here, the PROFINET IO device name is set as it was assigned for the IE switch during
PROFINET IO hardware configuration with NCM.
Figure 5-31 PNIO Configuration
This box shows the PROFINET IO application relation status; in other words, whether or not
the IE switch is connected "online" or "offline" with a PROFINET Controller.
In this context, online means that a connection to a PROFINET IO controller exists, that the
controller has downloaded its configuration data to the IE switch and that the device can
send status data to the PROFINET IO controller. In this status known as "in data exchange",
the parameters set with the PROFINET IO controller cannot be configured on the IE switch.
Here, you enter the PROFINET IO device name (Name of Station) according to the
configuration in HW Config.