SCALANCE X-200 
Configuration Manual, 03/2015, C79000-G8976-C285-06 
37 
  Configuration using WBM and CLI 
 
To make the best possible use of the technical possibilities of the IE switches, you can adapt 
the configuration of the device to the concrete situation in which it is used. There are two 
ways of configuring an IE switch: 
●  With the Command Line Interface (CLI), you can configure the IE switches via Telnet or 
SSH. An Ethernet connection is necessary. You can enable or disable Telnet or SSH 
using Web Based Management. 
●  Web Based Management (WBM) accesses the configuration of the IE switches using a 
Web browser. An Ethernet connection to the IE switch is necessary. 
 
Note 
Unauthorized access 
Depending on the selected configuration method, the following mechanisms are integrated to 
prevent unauthorized access to an IE switch:
 
  CLI via TELNET or SSH 
–  A CLI session is interrupted automatically if there is no input for certain length of time. 
In the factory settings, this is set to 300 seconds. You can increase this period to a 
maximum of 600 seconds. 
  WBM 
–  With the WBM, there is an automatic logout after a certain time. In the factory settings, 
this is set to 15 minutes. You can increase this period to a maximum of 60 minutes. 
–  In the top menu bar of the WBM user interface, you will see the "Logout" menu 
command. To log out manually, click this command. 
– 
Always exit a WBM sessions by clicking "Logout". Simply closing the browser you are 
using does not mean logging out and is therefore not secure. 
 
Note 
All the configuration 
changes are adopted in the flash memory after approximately 1 minute 
or after a warm restart. You should therefore run the "Restart" command in the command 
line interface or in Web Based Management before turning off the device. This ensures that 
all conf
iguration changes are saved. 
 
Note 
To use SNMP Management and traps, you require a network management station. This 
does not ship with the IE
 switch.