Menus in the WBM
5.4 The Switch menu
SCALANCE X-200
128 Configuration Manual, 03/2015, C79000-G8976-C285-06
5.4.4
Cable tester
Cable fault diagnostics
You can run fault diagnostics for the cables at each individual electrical Ethernet port. This
makes it possible to localize short-circuits and cable breaks.
This function is not possible with IRT devices.
To be able to run the fault diagnostics, the Ethernet cable must be plugged into the X-200.
There must, however, been no physical connection (link) to another network component.
Figure 5-39 Switch Port Diagnostics
Port
Select the port to which the cable you are testing is connected.
Run Test
This button activates the error diagnostics.
Pair
Displays the pair of wires in the cable.
Pairs 4-5 and 7-8 are not used.