Loading...
Menus in the WBM
5.4 The Switch menu
SCALANCE X-200
132 Configuration Manual, 03/2015, C79000-G8976-C285-06
The diagram itself is divided into the following areas:
White
There is an adequate link power margin for problem-free operation. When the X-200 IE
switch is installed, the link power margin should be in this range.
Yellow
If the link power margin enters this range, maintenance is necessary. The boundary of
the yellow area is at a link power margin of 2 dB. To ensure long-term functionality of the
system, the maintenance should be performed. If the link power margin is in the yellow
area, an event is triggered.
Orange
If the link power margin enters the orange range, urgent maintenance is necessary. The
boundary of the orange area is at a link power margin of 0 dB. If the link power margin is
in the orange range, an event is triggered and the FO LED of the relevant port lights up.
5.4.6
FDB
Switch Forwarding Database
This page shows which MAC addresses are currently reachable via which port.
The FDB is renewed when the aging time elapses.
Figure 5-42 Switch Forwarding Database