5.4 The Switch menu
SCALANCE X-200
Configuration Manual, 03/2015, C79000-G8976-C285-06
133
MAC Address
Shows the MAC addresses of the nodes that the IE switch has learned or the user has
created.
Ports
Shows the ports via which the MAC address is reachable.
The internal interface of the X-200 IE switch is called "C" in the FDB.
Status
Shows how the entry was created. The following values are possible:
static
The user created the entry.
Static addresses are stored permanently; in other words, they are not deleted when the
aging time expires or when the IE switch is restarted.
dynamic
The IE switch learned the entry.
When the aging time elapses or during a restart, dynamic entries are deleted again.
dcp
The entry was created for DCP.
In the factory settings, DCP is enabled on all ports.
si-time
The entry was created for SIMATIC Time.
In the factory settings, SIMATIC Time is disabled.