IRT communication with X-200
2
IRT - Isochronous Real Time
With STEP 7 as of V5.4, you can configure PROFINET devices that support data exchange
using IRT. To achieve the best possible synchronization and performance, IRT frames are
transferred deterministically via planned communication paths in a specified order.
Note
No port mirroring in IRT mode
Disable the function "Port Mirroring" in SCALANCE X
-200IRT devices if you want to operate
the device in IRT mode. IRT mode is not possible when the mirroring function is
enabled.
Supported devices and firmware versions
Topology-based IRT requires special network components that support planned data
transmission. The following devices of the SCALANCE X-200 product line support topology-
based IRT:
X200-4P IRT
X201-3P IRT
X201-3P IRT PRO
X202-2IRT
X202-2P IRT
X202-2P IRT PRO
X204IRT
X204IRT PRO
XF204IRT