EasyManua.ls Logo

Siemens SCALANCE X-200

Siemens SCALANCE X-200
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Menus in the WBM
5.3 The Agent menu
SCALANCE X-200
104 Configuration Manual, 03/2015, C79000-G8976-C285-06
Command
Description
Comment
secure <server no.>
<KeyID> <MD5 |
SHA> <key>
Specifies the key ID, the hash algorithm and the key
for secure communication with the NTP server.
Administrator only
security [E | D] Enables / disables checking the signature for commu-
nication with the NTP server.
Administrator only
5.3.13
Daylight Saving Time
Daylight Saving Time Table
On this page, you can control the daylight saving time changeover so that the system time is
correctly set for the local time zone.
You can define a rule for the daylight saving time changeover or specify a fixed date.
Figure 5-28 Daylight Saving Time Table
The table shows you an overview of the existing entries for the daylight saving time
changeover.
As soon as the end date of an entry is exceeded, if a rule is defined, the data for the next
changeover is displayed. With fixed entries, the row is deleted.