Menus in the WBM
5.3 The Agent menu
SCALANCE X-200
Configuration Manual, 03/2015, C79000-G8976-C285-06
105
Nr.
Shows the number of the entry.
If you create a new entry, a new row is created with a unique number.
Year
Shows the year for which the entry was created.
Start
Shows the month, day and time for the start of daylight saving time.
End
Shows the month, day and time for the end of daylight saving time.
Rec
Shows whether or not a rule was defined for the daylight saving time changeover:
x
A rule was defined for the daylight saving time changeover.
-
A fixed date was entered for the daylight saving time changeover.
Daylight Saving Time Table New Entry
Click the "New Entry" button on the "Daylight Saving Time Table" page.
Note
The content of this page depends on the selection
in the "Type" box.
Type
Select how the daylight saving time changeover is made:
Recurring
You can define a rule for the daylight saving time changeover.
This setting is suitable for regions in which the daylight saving time always begins or ends
on a particular weekday.
Date
You can define a fixed date for the daylight saving time changeover.
This setting is suitable for regions in which there is no rule governing the daylight saving
time changeover.