Menus in the WBM
5.3 The Agent menu
SCALANCE X-200
94 Configuration Manual, 03/2015, C79000-G8976-C285-06
Syntax of the Command Line Interface
Table 5- 20 Agent Configuration - CLI\AGENT>
Command
Description
Comment
ttimeout [E | D |
Timeout]
Enable, disable or specify the TELNET timeout. When speci-
fying the value, a range of 60 to 600 seconds is possible.
Administrator
only
wbmtime
[minutes]
Displays or specifies the time limit after which a WBM connec-
tion is reset. A maximum value of 999 minutes can be set.
The value 0 disables the time limit.
Administrator
only
5.3.10
Event Config
Agent Event Configuration
On this page, you specify how the X-200 IE switch reacts to system events. By selecting the
corresponding check boxes, you specify how the X-200 IE switch reacts to the various
events. The following options are available:
The IE Switch X-200 sends an e-mail.
The IE Switch X-200 triggers an SNMP trap.
The IE Switch X-200IRT saves the relevant event in the event table.