Menus in the WBM
5.4 The Switch menu
SCALANCE X-200
Configuration Manual, 03/2015, C79000-G8976-C285-06
125
The diagram itself is divided into the following areas:
White
The value for the received power of the optical link is OK.
Yellow
If the received power enters the yellow range, maintenance is required. The limit value
between the white and yellow area corresponds to the setting for "Rx Power Maintenance
required".
Orange
If the received power enters the orange range, urgent maintenance is necessary. The
limit value between the yellow and orange area corresponds to the setting for "Rx Power
Maintenance demanded".