EasyManuals Logo

Siemens SCALANCE X-200 Configuration Manual

Siemens SCALANCE X-200
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #151 background imageLoading...
Page #151 background image
Menus in the WBM
5.5 the Statistics menu
SCALANCE X-200
Configuration Manual, 03/2015, C79000-G8976-C285-06
151
Collisions
Indicates the number of collisions that have occurred.
Note
X
-200IRT IE switches work in the cut-through mode.
If a frame is received with a
bad checksum, the forwarding of the frame is aborted
prematurely and the frame is therefore shortened. The counter for CRC errors is
incremented.
If the frame involved is a frame with a length of 64 bytes, the counter for undersize errors is
also incremen
ted due to the shortening of the frame
Syntax of the Command Line Interface
Table 5- 42 Statistic Packet Error - CLI\INFORM>
Command
Description
Comment
errors
Displays statistical information on received errors.

Table of Contents

Other manuals for Siemens SCALANCE X-200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X-200 and is the answer not in the manual?

Siemens SCALANCE X-200 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X-200
CategorySwitch
LanguageEnglish

Related product manuals