MIBs for X-200
A.1 Important MIB variables
SCALANCE X-200
174 Configuration Manual, 03/2015, C79000-G8976-C285-06
Variables in the Interface directory
Variables
Access rights
Description
ifNumber Read only The number of different interfaces available in the component.
Possible values: 4...8.
ifDescr Read only A description and possibly additional information for a port. Possible value: string with a
maximum of 255 characters
ifType
Read only
The value ethernet-csmacd(6) or optical(65) is entered for SCALANCE X-200.
ifSpeed Read only Data transfer rate of the Ethernet port in bits per second. With SCALANCE X-200 devices,
this is either 10 Mbps or 100 Mbps.
ifOperStatus Read only The current operating status of the Ethernet port. The following values are possible:
up(1)
down(2)
ifLastChange Read only Length of time for which the selected port has been operating in the current status. The
value is shown in hundredths of a second.
ifInErrors Read only Number of received packages that were not forwarded to higher protocol layers because of
an error.
ifOutErrors
Read only
Number of packages that were not sent because of an error.

Table of Contents

Other manuals for Siemens SCALANCE X-200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X-200 and is the answer not in the manual?

Siemens SCALANCE X-200 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X-200
CategorySwitch
LanguageEnglish

Related product manuals