Menus in the WBM
5.1 The System menu
SCALANCE X-200
Configuration Manual, 03/2015, C79000-G8976-C285-06
51
Restart System
Click this button to restart the IE Switch X-200. You must confirm the restart in a dialog box.
During a restart, the IE Switch X-200 is reinitialized, the internal firmware is reloaded. The
learned entries in the address table are deleted. You can leave the browser window open
while the IE Switch X-200 restarts.
Memory Reset and Restart
Click on this button to restore the factory configuration settings with the exception of the
following parameters:
IP address
Subnet mask
IP address of the default router
DHCP flag
System Name
System Location
System Contact
PNIO Device Name
System Event Log Table
Settings for ring redundancy and standby
An automatic restart is triggered. In the user mode, this button is invisible.
Restore Factory Defaults and Restart
Click this button to restore the factory defaults for the configuration. The protected defaults
are also reset. In the user mode, this button is invisible.
Note
The IE Switch X
-200 must be given a new IP address before it can be accessed again.
Syntax of the Command Line Interface
Table 5- 3 System Restart & Defaults - CLI\SYSTEM\RESTARTS>
Command
Description
Comment
memreset
Restores the factory defaults. The protected settings are retained.
Administrator only
defaults Restores the factory defaults. The protected settings are also
reset.
Administrator only

Table of Contents