Menus in the WBM
5.1 The System menu
SCALANCE X-200
Configuration Manual, 03/2015, C79000-G8976-C285-06
53
By clicking "Save", you can save the event table (event log file) on the local computer.
Name and, if applicable, directory path of the file from which you want to load the new
firmware.
Note
Compatibility of the firmware versions
If you load firmware that is older than the firmware on the device, you will have to reset the
device to the
factory defaults after loading the firmware.
If you update the firmware of an IE Switch X
-200, make sure that the firmware in use is
compatible with the relevant device.
If incompatible firmware is downloaded to the device, it will no longer be possible to
operate
the device. In this case, compatible firmware will have to be loaded again with the boot
loader.
Note the following restrictions relating to the compatibility of the firmware versions with the
individual devices:
at least X-200IRT V3.1 X202-2P IRT PRO
at least X-200IRT V2.1 X200-4P IRT
X201-3P IRT
at least X-200 V4.1 XF204
XF204-2
XF206-1
Name of the file that contains the private key for SSL.
Name of the file that contains the certificate for SSL.
Here, you can save the private MIB of the IE switch X-200 in a file.