Menus in the WBM
5.1 The System menu
SCALANCE X-200
Configuration Manual, 03/2015, C79000-G8976-C285-06
63
Event Text
Displays a brief description of the event that has occurred.
If you have set the system time, the date and time of the event are also displayed.
Syntax of the Command Line Interface
Table 5- 9 System Event Log Table- CLI\SYSTEM\LOG>
Command
Description
Comment
info
Displays information on the log table configuration.
events <show|clear> Indicates or erases expired events in memory. Administrator only
eventmax [Max count] Specifies the maximum number of events in the log
table. A maximum of 10 to 400 entries can be set.
Administrator only