Note
Note the following when configuring an HRP ring:
If no HRP manager has been specified yet, the ring must be interrupted at one point. This
avoids circulating frames.
If an MRP ring is configured, at least one device must be set to the "Automatic
Redundancy Detection" or "MRP Manager (Auto)/Client" role. The role of the redundancy
manager is adopted automatically by a device with this setting.
If you change an MRP ring in the configuration to create an HRP ring, open the ring while
you reconfigure the devices. This avoids circulating frames.
Note
Note the following when configuring an MRP ring:
With devices having more than 8 ports, the selection of the ring ports when using MRP is
restricted:
With SCALANCE X216 and X224, ports 1 to 8 can be selected as MRP ring ports.
With SCALANCE X212-2 and X212-2LD, ports 9 to 14 can be selected as MRP ring
ports.
The default ring ports are adapted automatically if you select MRP. Make sure that the
ring ports are set correctly.
Syntax of the Command Line Interface
Table 5- 12 Ring Redundancy - CLI\X200\REDUND>
Command
Description
Comment
info
Displays information on the redundancy modules.
mode [A | AM | C | E | D] Sets the redundancy role:
A - Auto: MRP manager or MRP/HRP client
AM - Auto: MRP manager or MRP client
C - MRP client
E - HRP manager
D - HRP client
Administrator only
static [n-m] Specifies the static (fixed) ring port.
Note:
Only for the HRP manager and HRP client roles:
Specifies the static (fixed) ring port in the range n-m.
Administrator only
isolated [n-m] Specifies the isolated ring port.
Note:
Only for the HRP manager and HRP client roles:
Specifies the static (fixed) ring port in the range n-m.
Administrator only
rports [n-m | n-m] Specifies the two ring ports in the range n-m. Administrator only
clear Resets all redundancy counters to the original set-
ting.
Administrator only
redund [E | D]
Enables / disables ring redundancy.
Administrator only