Menus in the WBM
5.3 The Agent menu
SCALANCE X-200
Configuration Manual, 03/2015, C79000-G8976-C285-06
97
Syntax of the Command Line Interface
Table 5- 21 Agent Event Configuration - CLI\AGENT\EVENT>
Command
Description
Comment
info
Shows the current event configuration.
scontrol [C|A] Selects how the signaling contact works:
Conventional
An error/fault is displayed by the LED and
the signaling contact opens.
Aligned
The signaling contact can be opened or
closed as required regardless of a
fault/error.
Administrator only.
sclose [yes|no] Switches the signaling contact, if this in
"aligned" mode:
Yes
The contact is closed.
No:
The contact is opened
Administrator only.
setec
<Event|Index> <E|D> <E|D>
<E|D>
Specifies how an IE switch reacts to system
events. You can enter the following values
for the <Event> parameter:
Administrator only.
CW
Cold/Warm Start
LC
Link Change
AF
Authentication Failure
PM
Power M12 Change
FC
Fault State Change
RD
Redundancy Event
SB
Standby Event
LD
Loop Detection
FM
FMP Event
PO
POF Event
If an event is specified, the configured ac-
tions are formed for each event.
With the two parameters <E> or <D>, you
configure the reactions of the IE switch in the
order:
E-mail
Trap
Entry in the log table
Example: If you only want to send an e-mail
when there is a Link Change, enter the fol-
lowing command:
setec LC E D D

Table of Contents